HOW HOT IS THE HUMAN BODY? THERMOMETRY AND CALORIMETRY

Work Rate during Self-paced Exercise is not Mediated by the Rate of Heat Storage. Friesen BJ, Périard JD, Poirier MP, Lauzon M, Blondin DP, Haman F, Kenny GP. Med Sci Sports Exerc. 2018 Jan;50(1):159-168. doi: 10.1249/MSS.0000000000001421.: https://www.ncbi.nlm.nih.gov/pubmed/28902126


Are All Heat Loads Created Equal? Meade RD, Kenny GP. Med Sci Sports Exerc. 2017 Sep;49(9):1796-1804. doi: 10.1249/MSS.0000000000001309.: https://www.ncbi.nlm.nih.gov/pubmed/28452865


Heat remains unaccounted for in thermal physiology and climate change research. Flouris AD, Kenny GP. Version 2. F1000Res. 2017 Mar 6 [revised 2017 Jan 1];6:221. doi: 10.12688/f1000research.10554.2. eCollection 2017.: https://www.ncbi.nlm.nih.gov/pubmed/28357050


Non-invasive measurement of tibialis anterior muscle temperature during rest, cycling exercise and post-exercise recovery. Flouris AD, Dinas PC, Tsitoglou K, Patramani I, Koutedakis Y, Kenny GP. Physiol Meas. 2015 Jul;36(7):N103-13. doi: 10.1088/0967-3334/36/7/N103. Epub 2015 May 27.:

 https://www.ncbi.nlm.nih.gov/pubmed/26012697


Noninvasive assessment of muscle temperature during rest, exercise, and postexercise recovery in different environments. Flouris AD, Webb P, Kenny GP. J Appl Physiol (1985). 2015 May 15;118(10):1310-20. doi: 10.1152/japplphysiol.00932.2014. Epub 2015 Mar 26.:

 https://www.ncbi.nlm.nih.gov/pubmed/25814638


Temperature of Ingested Water during Exercise Does Not Affect Body Heat Storage. Lamarche DT, Meade RD, McGinn R, Poirier MP, Friesen BJ, Kenny GP. Med Sci Sports Exerc. 2015 Jun;47(6):1272-80. doi: 10.1249/MSS.0000000000000533.: https://www.ncbi.nlm.nih.gov/pubmed/25259541


The evaporative requirement for heat balance determines whole-body sweat rate during exercise under conditions permitting full evaporation. Gagnon D, Jay O, Kenny GP. J Physiol. 2013 Jun 1;591(11):2925-35. doi: 10.1113/jphysiol.2012.248823. Epub 2013 Mar 4.: https://www.ncbi.nlm.nih.gov/pubmed/23459754


Body heat storage during intermittent work in hot-dry and warm-wet environments. Stapleton JM, Wright HE, Hardcastle SG, Kenny GP. Appl Physiol Nutr Metab. 2012 Oct;37(5):840-9. doi: 10.1139/h2012-053. Epub 2012 Jun 12.: https://www.ncbi.nlm.nih.gov/pubmed/22686402


Exercise-rest cycles do not alter local and whole body heat loss responses. Gagnon D, Kenny GP. Am J Physiol Regul Integr Comp Physiol. 2011 Apr;300(4):R958-68. doi: 10.1152/ajpregu.00642.2010. Epub 2011 Jan 26.: https://www.ncbi.nlm.nih.gov/pubmed/21270343


Estimating changes in volume-weighted mean body temperature using thermometry with an individualized correction factor. Jay O, DuCharme MB, Webb P, Reardon FD, Kenny GP. Am J Physiol Regul Integr Comp Physiol. 2010 Aug;299(2):R387-94. doi: 10.1152/ajpregu.00546.2009. Epub 2010 May 26.: https://www.ncbi.nlm.nih.gov/pubmed/20504906


Aural canal, esophageal, and rectal temperatures during exertional heat stress and the subsequent recovery period. Gagnon D, Lemire BB, Jay O, Kenny GP. J Athl Train. 2010 Mar-Apr;45(2):157-63. doi: 10.4085/1062-6050-45.2.157.: https://www.ncbi.nlm.nih.gov/pubmed/20210619


Heat balance and cumulative heat storage during intermittent bouts of exercise. Kenny GP, Dorman LE, Webb P, Ducharme MB, Gagnon D, Reardon FD, Hardcastle SG, Jay O. Med Sci Sports Exerc. 2009 Mar;41(3):588-96. doi: 10.1249/MSS.0b013e31818c97a9.: https://www.ncbi.nlm.nih.gov/pubmed/19204592


Current evidence does not support an anticipatory regulation of exercise intensity mediated by rate of body heat storage. Jay O, Kenny GP. J Appl Physiol (1985). 2009 Aug;107(2):630-1. doi: 10.1152/japplphysiol.90632.2008. Epub 2008 Aug 7. No abstract available. :

 https://www.ncbi.nlm.nih.gov/pubmed/18687976


Calorimetric measurement of postexercise net heat loss and residual body heat storage. Kenny GP, Webb P, Ducharme MB, Reardon FD, Jay O. Med Sci Sports Exerc. 2008 Sep;40(9):1629-36. doi: 10.1249/MSS.0b013e31817751cb.: https://www.ncbi.nlm.nih.gov/pubmed/18685528


Estimating changes in mean body temperature for humans during exercise using core and skin temperatures is inaccurate even with a correction factor. Jay O, Reardon FD, Webb P, Ducharme MB, Ramsay T, Nettlefold L, Kenny GP. J Appl Physiol (1985). 2007 Aug;103(2):443-51. Epub 2007 May 10.:

 https://www.ncbi.nlm.nih.gov/pubmed/17495122


The Snellen human calorimeter revisited, re-engineered and upgraded: design and performance characteristics. Reardon FD, Leppik KE, Wegmann R, Webb P, Ducharme MB, Kenny GP. Med Biol Eng Comput. 2006 Aug;44(8):721-8. Epub 2006 Jul 25.: https://www.ncbi.nlm.nih.gov/pubmed/16937214


A three-compartment thermometry model for the improved estimation of changes in body heat content. Jay O, Gariépy LM, Reardon FD, Webb P, Ducharme MB, Ramsay T, Kenny GP. Am J Physiol Regul Integr Comp Physiol. 2007 Jan;292(1):R167-75. Epub 2006 Aug 24.: https://www.ncbi.nlm.nih.gov/pubmed/16931653


Insulation disks on the skin to estimate muscle temperature. Brajkovic D, Ducharme MB, Webb P, Reardon FD, Kenny GP. Eur J Appl Physiol. 2006 Aug;97(6):761-5. Epub 2006 May 24.:

 https://www.ncbi.nlm.nih.gov/pubmed/16721613


Muscle temperature transients before, during, and after exercise measured using an intramuscular multisensor probe. Kenny GP, Reardon FD, Zaleski W, Reardon ML, Haman F, Ducharme MB. J Appl Physiol (1985). 2003 Jun;94(6):2350-7. Epub 2003 Feb 21.: https://www.ncbi.nlm.nih.gov/pubmed/12598487


Tissue temperature transients in resting contra-lateral leg muscle tissue during isolated knee extension. Kenny GP, Reardon FD, Ducharme MB, Reardon ML, Zaleski W. Can J Appl Physiol. 2002 Dec;27(6):535-50.:

 https://www.ncbi.nlm.nih.gov/pubmed/12500993


A comparative analysis of physiological responses at submaximal workloads during different laboratory simulations of field cycling. Kenny GP, Reardon FD, Marion A, Thoden JS. Eur J Appl Physiol Occup Physiol. 1995;71(5):409-15.: https://www.ncbi.nlm.nih.gov/pubmed/8565972